Exhibit B: One-Line Plumbing Schematic
One-line plumbing schematic for the CUASCHEM5 feeder branch, vessel, flow control assembly, and return path.

Schematic Notes
- This schematic is a one-line functional diagram prepared from the declared CUASCHEM5 configuration and the stated field tie-in locations.
- The feeder vessel is used for TCCA tablet media only and does not provide acid feed.
- The feeder inlet connects on the higher-pressure line between the pump and the filter.
- The feeder outlet connects to the return line to the pool jets after the heater, flow meter, pressure gauge, feeder, and water feature branch piping where feasible.
- Circulation proof by pressure or flow is used to prevent feed valve opening when qualifying system circulation is not present.
- Check valves are provided at the inlet and outlet as part of the feeder branch isolation and depressurization arrangement.
Functional one-line schematic prepared for the CUASCHEM5 engineering compliance submission.
← Back to Compliance Dossier